  • FCC Approved / Superior Performing Radio Technology (900MHz, 866Mhz, 433MHz)
    Integrated into our sensor core technology is the TI CC111X family SoC. This family supports sub 1GHz GFSK digital modulation suitable in meeting FCC Part 15.247 in the USA and ETSI EN 301 409 in Europe with a +10dBm output power.
    • Supported frequencies by TI SoC:
      • ISM Band 902-928MHz
      • SDR Band 866-870kHz
      • ISM Band 433.05-434.79MHz

  • Advanced Power Management, Range and Data Structure
    We've gone to great lengths to optimize the performance of our RF boards well beyond the specifications set by the component manufacturers. This has allowed us to set-up advanced parameters that isolate the different tasks taking place on the hardware and only use the necessary components needed to execute each function to maximize the quality and reliability of our RF operation.

  • Variety of Pre-Configured Applications and New Application Development
    We already have over 24 unique sensor types and applications integrated into our OEM sensor platform, however, we understand that you may have a unique application where our pre-developed sensor may not have the code you need. Therefore, OEMSensors.com has a team of applications engineers and hardware/software developers ready to take your application to production. We're interested in seeing you succeed and our team is here to help you along the way.

OEM Wireless Sensors

 
 
 
OEM Wireless Temperature Sensor  

Wireless Temperature Sensor

The wireless temperature sensor uses a thermistor to accurately measure temperatures from -20°C to 85°C. Perfect for slower changing temperatures and critical applications such as facilities or rooms. User customization allows you to set the frequency of readings and the ability to set thresholds for "Alarms", "Alerts" and "FYIs".

  • Accurate to +/- 0.5°C (1.0°F).
  • Temperature range of -20°C to 85°C.
  • Custom leads are available for advanced sensor placement.
« Technical Specifications
OEM Wireless Temperature Sensor - Technical Specifications
Download Data Sheet Download Sensor Data Sheet
RF Board Specifications
Operating Frequency 900 MHz (25 Channels)
Device Transmission Range 300 - 500 ft. Non-LOS
Approximate Battery Life 300,000 Transmissions
(~ 2-5 Years Depending on Settings*)
Supply Voltage 2.0 - 3.6 VDC **
Current Consumption 0.7 μA (sleep mode)
2 mA (radio idle/off mode)
2 mA (measurement mode)
25 mA (radio RX mode)
35 mA (radio TX mode)
Operating Temperature Range -40°C to +85°C ( -40°F to +185°F ) ***
Optimal Battery Temperature Range (Coin Cell) +10°C to +60°C ( +50°F to +140°F )
Performance 0.7% BFSL Accuracy

* Battery life depends on sensor reporting frequency and other variables.
** At temperatures above 100°C, programmed memory can be lost.

Thermistor Specifications
Thermistor Operating Range -40°C to 125°C
Battery Operating Range -20°C to 85°C
Accuracy @ 25°C +/- 1%
Resistance @ 25°C 10K ± 1%
B-Constant (25°C – 50°C) 3380 ± 1%
Permissive Operating Current @ 25°C 0.38 mA
Rated Electric Power @ 25°C 15 mW
Dissipation Constant @ 25°C 1.5mW/°C
Time Constant @ 25°C 7 sec
RoHS Compliant
 
 
OEM Wireless Water Sensor  

Wireless Water Sensor

The wireless water sensor alerts you of potential property damage that results from flooding or leaks. Place this sensor anywhere flooding or faulty plumbing could cause a problem. This sensor can also be used to detect a lack of water, allowing you to know when a container is nearing empty.

  • Senses immediate pressence or non-pressence of water.
  • Can be used for detection of any non-cumbustable liquid.
  • Variety of lead lengths available.
« Technical Specifications
OEM Wireless Water Sensor - Technical Specifications
Download Data Sheet Download Sensor Data Sheet
RF Board Specifications
Operating Frequency 900 MHz (25 Channels)
Device Transmission Range 300 - 500 ft. Non-LOS
Approximate Battery Life 300,000 Transmissions
(~ 2-5 Years Depending on Settings*)
Supply Voltage 2.0 - 3.6 VDC **
Current Consumption 0.7 μA (sleep mode)
2 mA (radio idle/off mode)
2 mA (measurement mode)
25 mA (radio RX mode)
35 mA (radio TX mode)
Operating Temperature Range -40°C to +85°C ( -40°F to +185°F ) ***
Optimal Battery Temperature Range (Coin Cell) +10°C to +60°C ( +50°F to +140°F )
Performance 0.7% BFSL Accuracy

* Battery life depends on sensor reporting frequency and other variables.
** At temperatures above 100°C, programmed memory can be lost.

Water Sensor Specifications
Supply Voltage 2.0 - 3.6 V
Current Consumption 0.5 µA
Operating Temperature [-85°C to +150°C]
   
Absolute Maximum Ratings:
Supply Voltage: [-0.3 to 3.9 V]
Storage Temperature:  [-50°C to +150°C]*
*Core unprogrammed
 
 
OEM Wireless Light Sensor  

Wireless Light Sensor

The wireless light sensor can be user calibrated for baselines of light and dark, and will detect the pressence or non-pressence of light according to those baselines. Using our monitoring software, alerts can be setup for when a light threshold has been met.

  • Sense the pressence or non-pressence of light.
« Technical Specifications
OEM Wireless Light Sensor - Technical Specifications
Download Data Sheet Download Sensor Data Sheet
RF Board Specifications
Operating Frequency 900 MHz (25 Channels)
Device Transmission Range 300 - 500 ft. Non-LOS
Approximate Battery Life 300,000 Transmissions
(~ 2-5 Years Depending on Settings*)
Supply Voltage 2.0 - 3.6 VDC **
Current Consumption 0.7 μA (sleep mode)
2 mA (radio idle/off mode)
2 mA (measurement mode)
25 mA (radio RX mode)
35 mA (radio TX mode)
Operating Temperature Range -40°C to +85°C ( -40°F to +185°F ) ***
Optimal Battery Temperature Range (Coin Cell) +10°C to +60°C ( +50°F to +140°F )
Performance 0.7% BFSL Accuracy

* Battery life depends on sensor reporting frequency and other variables.
** At temperatures above 100°C, programmed memory can be lost.

Phototransistor Specifications
Collector Emitter Breakdown Voltage (0.1 mA) 6 V
Collector Dark Current (5 VCE) 3 nA typ.
Collector Emitter Capacitance (Vce=0, f=1MHz, E=0) 16 pF
Collector Light Current (5 VCE, 20 lx) 5 to 24µA 
Collector Light Current (5 VCE,100 lx) 75µA
Angle of Half Sensitivity ±50 degrees
Wavelength of Peak Sensitivity 570 nm
Range of Spectral Bandwidth 440 to 800 nm
Collector Emitter Saturation Voltage (20 lx, 1.2 µA) 0.1 V
RoHS Compliant
 
Absolute Maximum Ratings (Ta = 25 C)
Collector Emitter Voltage 6 V
Emitter Collector Voltage 1.5 V
Collector Current 20 mA
Power Dissipation 100 mW (Tamb≤55°C)
Junction Temperature 100 °C
Operating Temperature Range [-40°C to +85°C]
Storage Temperature Range [-40°C to +100°C]
Soldering Temperature 260°C (t≤5 s, 2 mm distance to package
Thermal Resistance Junction/Ambient 230 K/W (J-STD-051,soldered on PCB)
 
 
OEM Wireless Door/Window Sensor  

Wireless Open/Closed Sensor

The wireless open/closed sensor provides information on the status of doors, windows, cabinets, etc. Know if a building or area is being accessed when it should not be, or if a door or window has been left open.

  • Sense immediate access.
  • Sense if a door, window, drawer has been left open.
« Technical Specifications
OEM Wireless Open Closed Sensor - Technical Specifications
Download Data Sheet Download Sensor Data Sheet
RF Board Specifications
Operating Frequency 900 MHz (25 Channels)
Device Transmission Range 300 - 500 ft. Non-LOS
Approximate Battery Life 300,000 Transmissions
(~ 2-5 Years Depending on Settings*)
Supply Voltage 2.0 - 3.6 VDC **
Current Consumption 0.7 μA (sleep mode)
2 mA (radio idle/off mode)
2 mA (measurement mode)
25 mA (radio RX mode)
35 mA (radio TX mode)
Operating Temperature Range -40°C to +85°C ( -40°F to +185°F ) ***
Optimal Battery Temperature Range (Coin Cell) +10°C to +60°C ( +50°F to +140°F )
Performance 0.7% BFSL Accuracy

* Battery life depends on sensor reporting frequency and other variables.
** At temperatures above 100°C, programmed memory can be lost.

Movement Sensor Specifications
Supply Voltage 0.5 to 12VDC
Current Sink 0.00025 to 5 mA
Operating Temperature 0°C to 70°C
Sensitivity 0.05g – 0.10g OR 10g OR 35g OR 60g OR 150g
RoHS Compliant
 
Magnetic Sensor Specifications  
Power Supply Voltage -0.1 to 4.5 VDC
Output Current ± 5 mA
Power Dissipation 536 mW
Operate Point South: max 5 mT, North: - 5 mT
Release Point South: 0.6 mT, North: -0.6 mT
Period Max 100 mS
Supply Current 8.0 µA typ, 12.0 µA max
Operating Temperature -40°C to 85°C
Storage Temperature -40° to +125°C
RoHS Compliant
(Vdd = 1.80 V, Ta = 25 C)  
   
Absolute Maximum Ratings (Ta = 25 C)  
Power Supply Voltage [-0.1 - 4.5 V]
Output Current ± 0.5 mA
Operating Temperature -40°C to 85°C
Storage Temperature -40° to +125°C
 
 
OEM Wireless ID Sensor  

Wireless ID Sensor

The wireless ID sensor can be used as a digital ID tag for an object allowing you to track its contents and tell if it is on premises or not.

  • Measure the presence of an object or asset.
  • Assign contents to an object for tracking.
« Technical Specifications
OEM Wireless ID Sensor - Technical Specifications
Download Data Sheet Download Sensor Data Sheet
RF Board Specifications
Operating Frequency 900 MHz (25 Channels)
Device Transmission Range 300 - 500 ft. Non-LOS
Approximate Battery Life 300,000 Transmissions
(~ 2-5 Years Depending on Settings*)
Supply Voltage 2.0 - 3.6 VDC **
Current Consumption 0.7 μA (sleep mode)
2 mA (radio idle/off mode)
2 mA (measurement mode)
25 mA (radio RX mode)
35 mA (radio TX mode)
Operating Temperature Range -40°C to +85°C ( -40°F to +185°F ) ***
Optimal Battery Temperature Range (Coin Cell) +10°C to +60°C ( +50°F to +140°F )
Performance 0.7% BFSL Accuracy

* Battery life depends on sensor reporting frequency and other variables.
** At temperatures above 100°C, programmed memory can be lost.

Active RF ID Sensor Specifications
Supply Voltage 2.0 - 3.6 V
Current Consumption 0.7 µA (sleep mode)
Operating Temperature [-40°C to +85°C]
Storage Temperature:  [-50°C to +150°C]*
   
Absolute Maximum Ratings:
Supply Voltage: [-0.3 to 3.9 V]
*Core unprogrammed
 
 
OEM Wireless Magnetic Presence Sensor  

Wireless Magnetic Pressence Sensor

The wireless magnetic presence sensor can be used to detect the presence of a magnetic source. Place a magnet strip on a motor or machinery to measure movement and placement.

  • Measure and track RPMs.
  • Sense presence and movement.
« Technical Specifications
OEM Wireless Magnetic Sensor - Technical Specifications
Download Data Sheet Download Sensor Data Sheet
RF Board Specifications
Operating Frequency 900 MHz (25 Channels)
Device Transmission Range 300 - 500 ft. Non-LOS
Approximate Battery Life 300,000 Transmissions
(~ 2-5 Years Depending on Settings*)
Supply Voltage 2.0 - 3.6 VDC **
Current Consumption 0.7 μA (sleep mode)
2 mA (radio idle/off mode)
2 mA (measurement mode)
25 mA (radio RX mode)
35 mA (radio TX mode)
Operating Temperature Range -40°C to +85°C ( -40°F to +185°F ) ***
Optimal Battery Temperature Range (Coin Cell) +10°C to +60°C ( +50°F to +140°F )
Performance 0.7% BFSL Accuracy

* Battery life depends on sensor reporting frequency and other variables.
** Hardware can not withstand negative voltage. Take care when connecting a powered device.
*** At temperatures above 100°C, programmed memory can be lost.

Movement Sensor Specifications
Supply Voltage 0.5 to 12VDC
Current Sink 0.00025 to 5 mA
Operating Temperature 0°C to 70°C
Sensitivity 0.05g – 0.10g OR 10g OR 35g OR 60g OR 150g
RoHS Compliant
 
Magnetic Sensor Specifications  
Power Supply Voltage -0.1 to 4.5 VDC
Output Current ± 5 mA
Power Dissipation 536 mW
Operate Point South: max 5 mT, North: - 5 mT
Release Point South: 0.6 mT, North: -0.6 mT
Period Max 100 mS
Supply Current 8.0 µA typ, 12.0 µA max
Operating Temperature -40°C to 85°C
Storage Temperature -40° to +125°C
RoHS Compliant
(Vdd = 1.80 V, Ta = 25 C)  
   
Absolute Maximum Ratings (Ta = 25 C)  
Power Supply Voltage [-0.1 - 4.5 V]
Output Current ± 0.5 mA
Operating Temperature -40°C to 85°C
Storage Temperature -40° to +125°C
 
 
OEM Wireless Activity Sensor  

Wireless Activity Sensor

The wireless activity sensor detects sudden movement or non-movement of a given device or surface, and alerts you of the change.

  • Detect sudden movement.
  • Tell if a motor or machine is on or off.
« Technical Specifications
OEM Wireless Activity Sensor - Technical Specifications
Download Data Sheet Download Sensor Data Sheet
RF Board Specifications
Operating Frequency 900 MHz (25 Channels)
Device Transmission Range 300 - 500 ft. Non-LOS
Approximate Battery Life 300,000 Transmissions
(~ 2-5 Years Depending on Settings*)
Supply Voltage 2.0 - 3.6 VDC **
Current Consumption 0.7 μA (sleep mode)
2 mA (radio idle/off mode)
2 mA (measurement mode)
25 mA (radio RX mode)
35 mA (radio TX mode)
Operating Temperature Range -40°C to +85°C ( -40°F to +185°F ) ***
Optimal Battery Temperature Range (Coin Cell) +10°C to +60°C ( +50°F to +140°F )
Performance 0.7% BFSL Accuracy

* Battery life depends on sensor reporting frequency and other variables.
** At temperatures above 100°C, programmed memory can be lost.

Activity Sensor Specifications
Supply Voltage 0.5 to 12VDC
Current Sink 0.00025 to 5 mA
Operating Temperature 0°C to 70°C
Sensitivity 0.05g – 0.10g / 10g / 35g / 60g / 150g
RoHS Compliant
 
 
OEM Wireless Dry Contact Sensor  

Wireless Dry Contact Sensor

The wireless dry contact sensor can be used to detect contact between two wired contact points. This sensors can be used with an external mechanical switch or a contact plate.

  • Senses immediate contact between wires.
  • Senses when contact is broken.
  • 36in. lead length.
« Technical Specifications
OEM Wireless Dry Contact Sensor - Technical Specifications
Download Data Sheet Download Sensor Data Sheet
RF Board Specifications
Operating Frequency 900 MHz (25 Channels)
Device Transmission Range 300 - 500 ft. Non-LOS
Approximate Battery Life 300,000 Transmissions
(~ 2-5 Years Depending on Settings*)
Supply Voltage 2.0 - 3.6 VDC **
Current Consumption 0.7 μA (sleep mode)
2 mA (radio idle/off mode)
2 mA (measurement mode)
25 mA (radio RX mode)
35 mA (radio TX mode)
Operating Temperature Range -40°C to +85°C ( -40°F to +185°F ) ***
Optimal Battery Temperature Range (Coin Cell) +10°C to +60°C ( +50°F to +140°F )
Performance 0.7% BFSL Accuracy

* Battery life depends on sensor reporting frequency and other variables.
** Hardware can not withstand negative voltage. Take care when connecting a powered device.
*** At temperatures above 100°C, programmed memory can be lost.

Dry Contact Sensor Specifications
Supply Voltage 2.0 - 3.6 V
Current Consumption 0.7 µA
Operating Temperature [-85°C to +150°C]
   
Absolute Maximum Ratings:
Supply Voltage: [-0.3 to 3.9 V]
Storage Temperature:  [-50°C to +150°C]*
*Core unprogrammed
 
 
OEM Wireless Accelerometer  

Wireless Accelerometer

The wireless accelerometer activates at given time intervals to measure the intensity and frequency of movement. Place this sensor on constantly moving objects to take periodic readings of their movement.

  • Activated at set time intervals.
  • Measures intensity and frequency of movement.
  • User defined thresholds.
« Technical Specifications
OEM Wireless Accelerometer - Technical Specifications
Download Data Sheet Download Sensor Data Sheet
RF Board Specifications
Operating Frequency 900 MHz (25 Channels)
Device Transmission Range 300 - 500 ft. Non-LOS
Approximate Battery Life 300,000 Transmissions
(~ 2-5 Years Depending on Settings*)
Supply Voltage 2.0 - 3.6 VDC **
Current Consumption 0.7 μA (sleep mode)
2 mA (radio idle/off mode)
2 mA (measurement mode)
25 mA (radio RX mode)
35 mA (radio TX mode)
Operating Temperature Range -40°C to +85°C ( -40°F to +185°F ) ***
Optimal Battery Temperature Range (Coin Cell) +10°C to +60°C ( +50°F to +140°F )
Performance 0.7% BFSL Accuracy

* Battery life depends on sensor reporting frequency and other variables.
** At temperatures above 100°C, programmed memory can be lost.

Accelerometer Specifications
Supply Voltage 2.4 – 3.6 V
Supply Current Drain (Operation mode, Pulse Detect Function Mode) 400 µA
Supply Current Drain (Standby mode) 2.5 µA
Operating Temperature -40ºC to 85ºC
Sensitivity 58-70 count/g
Self Test Output Response 32 - 83 count
Temperature Compensation for Offset ±0.5 mg/°C (typ)
Temperature Sensitivity for Offset ±0.01 mg/°C (typ)
Input High Voltage 0.7 x Vdd
Input Low Voltage 0.35 x Vdd
Internal Clock Frequency 140 – 160 kHz
Bandwidth for Data Measurement 62.5 Hz or 125 Hz
Output Data Rate 125 Hz or 250 Hz
Nonlinearity (2 g range) -1 to +1 %FS
Cross Axis Sensitivity -5 to +5 %
RoHS Compliant
(-40°C ≤ Ta ≤ 85°C, 2.4 V ≤ Avdd ≤ 3.6 V,
Acceleration = 0g, Loaded Input)
   
Maximum Ratings  
Maximum Acceleration (all axes) 5000 g
Analog Supply Voltage [-0.3 to +3.6 V]
Digital I/O pins Supply Voltage [-0.3 to +3.6 V]
Drop Test 1.8 m
Storage Temperature Range [-40°C to +125°C]
 
 
OEM Wireless Humidity Sensor  

Wireless Humidity Sensor

The wireless humidity sensor allows you to monitor the relative humidity of the air within a room or enclosure. Ideal for monitoring humidity within greenhouses, industrial spaces, museums, saunas and humidors. They can also be used for residential applications such as controlling mold, mildew or dust mites.

  • Activated at set time intervals.
  • Measures temperature and relative humidity.
  • User defined thresholds.
« Technical Specifications
OEM Wireless Humidity Sensor - Technical Specifications
Download Data Sheet Download Sensor Data Sheet
RF Board Specifications
Operating Frequency 900 MHz (25 Channels)
Device Transmission Range 300 - 500 ft. Non-LOS
Approximate Battery Life 300,000 Transmissions
(~ 2-5 Years Depending on Settings*)
Supply Voltage 2.0 - 3.6 VDC **
Current Consumption 0.7 μA (sleep mode)
2 mA (radio idle/off mode)
2 mA (measurement mode)
25 mA (radio RX mode)
35 mA (radio TX mode)
Operating Temperature Range -40°C to +85°C ( -40°F to +185°F ) ***
Optimal Battery Temperature Range (Coin Cell) +10°C to +60°C ( +50°F to +140°F )
Performance 0.7% BFSL Accuracy

* Battery life depends on sensor reporting frequency and other variables.
** At temperatures above 100°C, programmed memory can be lost.

Humidity Sensor Specifications
Accuracy: +/- 2% under normal conditions (50% - 90% RH)
Energy consumption: 80uW (at 12bit, 3V, 1 measurement / s)
RH operating range: 0 – 100% RH
T operating range: -40 – +125°C (-40 – +257°F)
RH response time: 8 sec (tau63%)
Maximal accuracy limits for relative humdity and temperature:
Relative Humidity Accuracy
 
 
OEM Wireless Button Sensor  

Wireless Button Sensor

The touch activated wireless button sensor allows a notification signal to be sent when immediate contact is important. This button includes an LED response indicator to confirm that the system has received the alert.

  • Manually triggered push button.
  • LED response indicator.
« Technical Specifications
OEM Wireless Button Sensor - Technical Specifications
Download Data Sheet Download Sensor Data Sheet
RF Board Specifications
Operating Frequency 900 MHz (25 Channels)
Device Transmission Range 300 - 500 ft. Non-LOS
Approximate Battery Life 300,000 Transmissions
(~ 2-5 Years Depending on Settings*)
Supply Voltage 2.0 - 3.6 VDC **
Current Consumption 0.7 μA (sleep mode)
2 mA (radio idle/off mode)
2 mA (measurement mode)
25 mA (radio RX mode)
35 mA (radio TX mode)
Operating Temperature Range -40°C to +85°C ( -40°F to +185°F ) ***
Optimal Battery Temperature Range (Coin Cell) +10°C to +60°C ( +50°F to +140°F )
Performance 0.7% BFSL Accuracy

* Battery life depends on sensor reporting frequency and other variables.
** At temperatures above 100°C, programmed memory can be lost.

Button Specifications (Single Pole Switch)
Type Single Pole, Single Throw (SPST)
Switch Function Off-Momentary (Normally open)
Electrical Life 10,000,000 cycles
Contact Rating 50mA @ 24VDC
Operating Temperature [-40°C to +115°C]
RoHS Compliant
   
LED Specifications  
Lens Type White Diffused
Viewing Angle 35°
Peak Wavelength (IF = 20 mA) Red: 660 nm
  Green: 565 nm
Dominant Wavelength (IF = 20 mA) Red: 640 nm
  Green: 568
Spectral Line Half-Width (IF = 20 mA) Red: 20
  Green: 30
Capacitance (VF = 0V; f = 1MHz) Red: 45 pF
  Green: 15 pF
Forward Voltage (IF = 20 mA) Red: 1.85 V
  Green: 2.2 V
Power Dissipation (Absolute Max) Red: 75 mW
  Green: 62.5 mW
DC Forward Current Red: 30 mA
  Green: 62.5 mW
Peak Forward Current Red: 155 mA
  Green: 140 mA
Operating/Storage Temperature -40°C to +85°C
RoHS Compliant
Ta = 25 C
   
Absolute Maximum Ratings (Ta = 25 C)
Power Dissipation Red 75 mW
  Green 62.5 mW
DC Forward Current Red 30 mA
  Green 25 mA
Peak Forward Current Red 155 mA
1/10 duty cycle, 0.1 ms pulse width Green 140 mA
Operating / Storage Temperature [-40°C to +85°C]
Lead Solder Temperature (2mm below) 260°C for 3 seconds
Lead Solder Temperature (5mm below) 260°C for 5 seconds
 
 
OEM Wireless Motion Sensor  

Wireless Motion Sensor

The wireless motion sensor uses an infrared sensor to accurately detect movements made by people/animals within 16.4 ft (5 m) range.

  • Passive Infrared Technology.
  • Sensing Range of 16.4 ft (5 m).
« Technical Specifications
OEM Wireless Motion Sensor - Technical Specifications
Download Data Sheet Download Sensor Data Sheet
RF Board Specifications
Operating Frequency 900 MHz (25 Channels)
Device Transmission Range 300 - 500 ft. Non-LOS
Approximate Battery Life 300,000 Transmissions
(~ 2-5 Years Depending on Settings*)
Supply Voltage 2.0 - 3.6 VDC **
Current Consumption 0.7 μA (sleep mode)
2 mA (radio idle/off mode)
2 mA (measurement mode)
25 mA (radio RX mode)
35 mA (radio TX mode)
Operating Temperature Range -40°C to +85°C ( -40°F to +185°F ) ***
Optimal Battery Temperature Range (Coin Cell) +10°C to +60°C ( +50°F to +140°F )
Performance 0.7% BFSL Accuracy

* Battery life depends on sensor reporting frequency and other variables.
*** At temperatures above 100°C, programmed memory can be lost.

Infrared Motion Sensor Specifications
Sensing Technology Passive Infrared
Sensing Range 16.4 ft (5 m)
Voltage Rating 3 VDC to 6 VDC
Temperature Range –20 to +60°C (–4 to +140°F)
Output Type Digital
Supply Current 170 uA
 
 
OEM Wireless Lux Sensor  

Wireless Lux Sensor

The wireless Lux sensor measures the intensity of light in lux (luminescence/unit area), from 0 – 1000 lux (indoor range). Perfect for light sensitive applications like museum and art gallery light monitoring.

  • Highly sensitive photodiode.
  • Measure luminescence from 0 – 1000 lux (indoor range).
« Technical Specifications
OEM Wireless Lux Sensor - Technical Specifications
Download Data Sheet Download Sensor Data Sheet
RF Board Specifications
Operating Frequency 900 MHz (25 Channels)
Device Transmission Range 300 - 500 ft. Non-LOS
Approximate Battery Life 300,000 Transmissions
(~ 2-5 Years Depending on Settings*)
Supply Voltage 2.0 - 3.6 VDC **
Current Consumption 0.7 μA (sleep mode)
2 mA (radio idle/off mode)
2 mA (measurement mode)
25 mA (radio RX mode)
35 mA (radio TX mode)
Operating Temperature Range -40°C to +85°C ( -40°F to +185°F ) ***
Optimal Battery Temperature Range (Coin Cell) +10°C to +60°C ( +50°F to +140°F )
Performance 0.7% BFSL Accuracy

* Battery life depends on sensor reporting frequency and other variables.
*** At temperatures above 100°C, programmed memory can be lost.

Lux Sensor Specifications
Sensor Technology High Sensitive Photodiode
Material Silicon
Peak Wavelength 580 nm
Maximum Reverse Voltage 6 V
Maximum Power Dissipation 40 mW
Maximum Light Current 500 uA
Maximum Rise Time 8.5 ms
Maximum Fall Time 8.5 ms
Maximum Operating Temperature Range -30°C to +85°C
RoHS Compliant
 
 
OEM Wireless 0-20 mA Sensor  

Wireless 0-20 mA Sensor

The wireless 0-20 mA sensor is capable of measuring the current off another device or sensor, up to 20mA (DC), by connecting the leads on the Monnit WIT 0-20mA Current sensor to the positive and ground terminals of the device being measured. Examples of interfacing devices include, but are not limited to: Current transducers (CTs) with outputs up to 20 mA, pH sensor, dissolved oxygen sensor, pressure sensor, magnetic flow meters, velocity or acceleration sensors, industrial vibration sensors, industrial accelerometers, any kind of sensor that specifies the output is in (mA) within the range of 0 – 20.

  • Interfaces with sensors or devices between 0-20 mA.
« Technical Specifications
OEM Wireless 0-20 mA Sensor - Technical Specifications
Download Data Sheet Download Sensor Data Sheet
RF Board Specifications
Operating Frequency 900 MHz (25 Channels)
Device Transmission Range 300 - 500 ft. Non-LOS
Approximate Battery Life 300,000 Transmissions
(~ 2-5 Years Depending on Settings*)
Supply Voltage 2.0 - 3.6 VDC **
Current Consumption 0.7 μA (sleep mode)
2 mA (radio idle/off mode)
2 mA (measurement mode)
25 mA (radio RX mode)
35 mA (radio TX mode)
Operating Temperature Range -40°C to +85°C ( -40°F to +185°F ) ***
Optimal Battery Temperature Range (Coin Cell) +10°C to +60°C ( +50°F to +140°F )
Performance 0.7% BFSL Accuracy

* Battery life depends on sensor reporting frequency and other variables.
*** At temperatures above 100°C, programmed memory can be lost.

 
 
OEM Wireless Analog Voltage Sensor  

Wireless Analog Voltage Sensor

The wireless analog voltage sensor interface is capable of measuring the voltage off another device, battery, or sensor, up to 1.25 DCV by connecting the leads on the Monnit WIT Analog Voltage sensor to the positive and ground terminals of the device being measured. Examples of interfacing devices include, but are not limited to: Strain Gauge, Pressure Transducer, RTD, Thermistor, or Thermocouple, Piezo Electric sensors, Photoresistor, Industrial Accelerometer, any kind of variable resistor, any kind of sensor that outputs a voltage, etc. If the device being measured is passive, the user must supply their own excitation voltage, as the Monnit WIT Analog Voltage sensor is really just a "voltage observer". Cannot be used for AC voltage measurement.

  • Interfaces with other devices up to 1.25 DCV.
« Technical Specifications
OEM Wireless Analog Sensor - Technical Specifications
Download Data Sheet Download Sensor Data Sheet
RF Board Specifications
Operating Frequency 900 MHz (25 Channels)
Device Transmission Range 300 - 500 ft. Non-LOS
Approximate Battery Life 300,000 Transmissions
(~ 2-5 Years Depending on Settings*)
Supply Voltage 2.0 - 3.6 VDC **
Current Consumption 0.7 μA (sleep mode)
2 mA (radio idle/off mode)
2 mA (measurement mode)
25 mA (radio RX mode)
35 mA (radio TX mode)
Operating Temperature Range -40°C to +85°C ( -40°F to +185°F ) ***
Optimal Battery Temperature Range (Coin Cell) +10°C to +60°C ( +50°F to +140°F )
Performance 0.7% BFSL Accuracy

* Battery life depends on sensor reporting frequency and other variables.
*** At temperatures above 100°C, programmed memory can be lost.

 
 
OEM Wireless Voltage Detection Sensor  

Wireless Voltage Detection Sensor

The analog voltage detection sensor notifies of the presence or absence of electricity. It is intended for use on power sources or power supplies of 120 VAC. Not intended for voltages higher than 150 VAC and also not intended for use with DC sources. Perfect for sump pump monitoring. This sensor triggers on the state change from presence to absence and vice versa. The data displayed is either "No Voltage" or "Voltage Detected".

  • Interfaces with other devices or power lines up to 150 VAC.
« Technical Specifications
OEM Wireless Voltage Detection Sensor - Technical Specifications
Download Data Sheet Download Sensor Data Sheet
RF Board Specifications
Operating Frequency 900 MHz (25 Channels)
Device Transmission Range 300 - 500 ft. Non-LOS
Approximate Battery Life 300,000 Transmissions
(~ 2-5 Years Depending on Settings*)
Supply Voltage 2.0 - 3.6 VDC **
Current Consumption 0.7 μA (sleep mode)
2 mA (radio idle/off mode)
2 mA (measurement mode)
25 mA (radio RX mode)
35 mA (radio TX mode)
Operating Temperature Range -40°C to +85°C ( -40°F to +185°F ) ***
Optimal Battery Temperature Range (Coin Cell) +10°C to +60°C ( +50°F to +140°F )
Performance 0.7% BFSL Accuracy

* Battery life depends on sensor reporting frequency and other variables.
*** At temperatures above 100°C, programmed memory can be lost.

 
 
OEM Wireless Voltage Measurement Sensor  

Wireless Voltage Measurement Sensor

The voltage measurement sensor is an analog measuring device that reports the measured voltage on user specified intervals. The sensor has three operating modes, in which you can obtain the voltage measurement in VACrms (root mean squared), the peak voltage, or the DC voltage. The modes can be set by the user; the default mode measures VACrms.

  • Interfaces with other devices up to 500 VAC/VDC.
« Technical Specifications
OEM Wireless Voltage Measurement Sensor - Technical Specifications
Download Data Sheet Download Sensor Data Sheet
RF Board Specifications
Operating Frequency 900 MHz (25 Channels)
Device Transmission Range 300 - 500 ft. Non-LOS
Approximate Battery Life 300,000 Transmissions
(~ 2-5 Years Depending on Settings*)
Supply Voltage 2.0 - 3.6 VDC **
Current Consumption 0.7 μA (sleep mode)
2 mA (radio idle/off mode)
2 mA (measurement mode)
25 mA (radio RX mode)
35 mA (radio TX mode)
Operating Temperature Range -40°C to +85°C ( -40°F to +185°F ) ***
Optimal Battery Temperature Range (Coin Cell) +10°C to +60°C ( +50°F to +140°F )
Performance 0.7% BFSL Accuracy

* Battery life depends on sensor reporting frequency and other variables.
*** At temperatures above 100°C, programmed memory can be lost.

 
 
OEM Wireless Flex Sensor  

Wireless Flex Sensor

The wireless flex sensor uses a flexible, stress sensitive ribbon to accurately measure the amount of bend (force) applied to the ribbon. Perfect for measurement of mechanical movement, air flow, water flow, or even vibration.

  • Bend Sensor / Potentiometer.
« Technical Specifications
OEM Wireless Flex Sensor - Technical Specifications
Download Data Sheet Download Sensor Data Sheet
RF Board Specifications
Operating Frequency 900 MHz (25 Channels)
Device Transmission Range 300 - 500 ft. Non-LOS
Approximate Battery Life 300,000 Transmissions
(~ 2-5 Years Depending on Settings*)
Supply Voltage 2.0 - 3.6 VDC **
Current Consumption 0.7 μA (sleep mode)
2 mA (radio idle/off mode)
2 mA (measurement mode)
25 mA (radio RX mode)
35 mA (radio TX mode)
Operating Temperature Range -40°C to +85°C ( -40°F to +185°F ) ***
Optimal Battery Temperature Range (Coin Cell) +10°C to +60°C ( +50°F to +140°F )
Performance 0.7% BFSL Accuracy

* Battery life depends on sensor reporting frequency and other variables.
*** At temperatures above 100°C, programmed memory can be lost.

Flex Sensor Specifications
Sensor Type Bend / Potentiometer
Sensor Operating Range -40°C to 90°C @ 90% RH typ.
Sensor Storage Temperature -60°C to 110°C @ 90% RH typ.
Base Resistance 100 Ω - 500 KΩ
 
 
OEM Wireless Grains Per Pound Sensor  

Wireless Grains Per Pound Sensor

The wireless grains per pound sensor measures the mass in grains of H2O in otherwise dry air. Put simplistically, the measurement is the weight of water in air. This sensor uses a calibrated humidity sensor to obtain the absolute humidity at the current temperature and converts that value into the Grains per Pound measurement displayed.

  • Measures the weight of water in air.
  • Uses a calibrated humidity sensor.
« Technical Specifications
OEM Wireless Grains Per Pound Sensor - Technical Specifications
RF Board Specifications
Operating Frequency 900 MHz (25 Channels)
Device Transmission Range 300 - 500 ft. Non-LOS
Approximate Battery Life 300,000 Transmissions
(~ 2-5 Years Depending on Settings*)
Supply Voltage 2.0 - 3.6 VDC **
Current Consumption 0.7 μA (sleep mode)
2 mA (radio idle/off mode)
2 mA (measurement mode)
25 mA (radio RX mode)
35 mA (radio TX mode)
Operating Temperature Range -40°C to +85°C ( -40°F to +185°F ) ***
Optimal Battery Temperature Range (Coin Cell) +10°C to +60°C ( +50°F to +140°F )
Performance 0.7% BFSL Accuracy

* Battery life depends on sensor reporting frequency and other variables.
*** At temperatures above 100°C, programmed memory can be lost.

Humidity Sensor Specifications
Accuracy: +/- 2% under normal conditions (50% - 90% RH)
Energy consumption: 80uW (at 12bit, 3V, 1 measurement / s)
RH operating range: 0 – 100% RH
T operating range: -40 – +125°C (-40 – +257°F)
RH response time: 8 sec (tau63%)
Maximal accuracy limits for relative humdity and temperature:
Relative Humidity Accuracy
 
 
OEM Wireless Liquid Level Sensor  

Wireless Liquid Level Sensor

The wireless liquid level sensor uses a solid-state, resistance sensitive ribbon sensor to measure the level of a liquid in a container.

  • Liquid sensitive ribbon sensor.
  • Resolution of liquid level: 1/32 in.
« Technical Specifications
OEM Wireless Liquid Level Sensor - Technical Specifications
Download Data Sheet Download Sensor Data Sheet
RF Board Specifications
Operating Frequency 900 MHz (25 Channels)
Device Transmission Range 300 - 500 ft. Non-LOS
Approximate Battery Life 300,000 Transmissions
(~ 2-5 Years Depending on Settings*)
Supply Voltage 2.0 - 3.6 VDC **
Current Consumption 0.7 μA (sleep mode)
2 mA (radio idle/off mode)
2 mA (measurement mode)
25 mA (radio RX mode)
35 mA (radio TX mode)
Operating Temperature Range -40°C to +85°C ( -40°F to +185°F ) ***
Optimal Battery Temperature Range (Coin Cell) +10°C to +60°C ( +50°F to +140°F )
Performance 0.7% BFSL Accuracy

* Battery life depends on sensor reporting frequency and other variables.
*** At temperatures above 100°C, programmed memory can be lost.

Liquid Level Sensor Specifications
Sensor Material Polyethylene Terephthalate (PET)
Operating Temperature Range -9°C to 60°C (15°F to 140°F)
Sensor Length 10.1 inch (256.5 mm)
Active Sensor Length: 8.6 inch (218.4 mm))
Sensor Width 1.0 inch (25.4 mm)
Sensor Thickness 0.015 inch (0.381 mm)
Actuation Depth Nominal 1 inch (25.4 mm)
Resolution 1/32 inch (0.794 mm)
 
 
OEM Wireless Pressure Sensor  

Wireless Pressure Sensor

The Wireless Pressure Sensor is capable of measuring gas, liquid or vapor pressures from 0-160 PSI. This sensor can be used anywhere a pressure gauge can be used. Requires 12 – 32 VDC input. This solution combines a standard pressure transducer interfaced to an OEM Sensor wireless radio.

  • Measure pressure from 0-160 PSI.
  • Measure gas, liquid or vapor pressures.
  • Pressure transducer is NEMA 4X, CE rated.
« Technical Specifications
OEM Wireless Pressure Sensor - Technical Specifications
Download Data Sheet Download Sensor Data Sheet
RF Board Specifications
Operating Frequency 900 MHz (25 Channels)
Device Transmission Range 300 - 500 ft. Non-LOS
Approximate Battery Life 300,000 Transmissions
(~ 2-5 Years Depending on Settings*)
Supply Voltage 2.0 - 3.6 VDC **
Current Consumption 0.7 μA (sleep mode)
2 mA (radio idle/off mode)
2 mA (measurement mode)
25 mA (radio RX mode)
35 mA (radio TX mode)
Operating Temperature Range -40°C to +85°C ( -40°F to +185°F ) ***
Optimal Battery Temperature Range (Coin Cell) +10°C to +60°C ( +50°F to +140°F )
Performance 0.7% BFSL Accuracy

* Battery life depends on sensor reporting frequency and other variables.
*** At temperatures above 100°C, programmed memory can be lost.

Pressure Sensor Specifications
Thermal Effect on Reading 2% per 100 ºF
Media Gas, Liquid or Vapor
Dial Size 2" (50.8 mm)
Gauge Accuracy 1.6% full-scale Grade A (50.8 mm)
Process Connection ¼" NPT
Proof Pressure 0 to 160 psi = 150% of full scale
Burst Pressure 0 to 160 psi = 10x burst
Window Polycarbonate or Safety Glass
Case 304 Series Stainless Steel
Socket and Tube 316 Series Stainless Steel
Gauge Movement Suppressed Stop Movement for True Electrical Zero Reading
 
 
 

Request More Information

Please provide as much information as possible.

Your Contact Information.

Name
Company
E-mail Address
Phone
 
Contact me by
 

We understand that we may not have exactly what you need, but we're getting there. Fill out this form and we'll get you a quote to have our team develop your new unique wireless sensor and application profile.

 
Types and Quantities of Sensors Needed
Please provide a brief description of the types of sensors, gateways and software you are intested in, be sure to include quantities to get a more accurate quote.
 
Description of Application(s)
Please decribe the application(s) for using sensors. If you are requesting new sensor and application development please describe the new application and how the sensors must perform.
 
Additional Notes or Comments